Compact bypass switch, lockable, for bypassing bolt and cabin door contact
According to EN81-20 5.12.1.8, for maintenance activities on landing door, car door and door locking contacts, an electrical bypass facility must be available in the lift control system for emergencies and tests. This device has to be a switch protected against unintentional actuation by permanently installed mechanically movable means (e.g. cover), which complies with the requirements for an electrical safety device according to 5.11.2.
The compact W+W bypass switches are mounted on the DIN rail in the switch cabinet. The lockable cover prevents unintentional actuation.
0: Normal position
1: Bypass car door
2: Bypass landing door (bolt contact)
3: Bypass landing door (door contact, for hinged doors)
| Technical data: | The technical data is listed for the respective products, art.no. 050660, 050663, 050665 and 050667. |
| Description |
|---|
|
Bypass switch V1 0-1-2 (050660) Bypass switch V1, 3 switch positions (0-1-2) for bypassing bolt contact and door contact, lockable. |
|
Bypass switch V2 0-1-2-3 (050663) Bypass switch V2, 4 switch positions (0-1-2-3) for bypassing bolt contact and door contact, lockable. |
|
Bypass switch V1 0-1-2-3 (050665) Bypass switch V1, 4 switch positions (0-1-2-3) for bypassing the doors. For mounting on a 35 mm top hat rail (EN 50022), the cover is lockable. |
|
Bypass switch V3 0-1-2-3 (050667) Bypass switch V3, 4 switch positions (0-1-2-3) for bypassing the doors. For mounting on a 35 mm top hat rail (EN 50022), the cover is lockable. |