Bare, fine gauge copper strand.
Lead insulation: PVC.
Lead designation acc. to DIN 47100.
Twisted pair leads, pairs stranded in layers.
Plastic foil around the conductor bunch.
Shielding braid of tinned copper, covering degree approx. 85 %.
Sheath: PVC, flame retardant and self-extinguishing acc. to IEC 60332-1-2.
In dry, damp and wet rooms, over, at, in and under the plaster.
In stonework and concrete, but not in vibrated, jolted or compressed concrete.
These cables should be preferably installed in installation
tubes or cable ducts.
Data cable in general.
Connection line to incremental and absolute encoders.
According to the Low Voltage Directive 2014/35/EU.
Deliverable as cut goods.
| Bending radius | 5 x outer diameter |
| Rated voltage | 350V (not for high voltage use) |
| Impedance | 78 Ω |
| Capacitive coupling | max. 300 pF/100m at 800 Hz |
| Inductance | approx. 0.65 mH/km |
| Temperature range | fixed installation: -30°C up to +70°C |
| Description |
|---|
|
LiYCY(TP) 3x2x0.5mm² (051388) Data cable shielded LiYCY(TP) 3x2x0.5mm², twisted pair, lead colour/no. according to DIN 47100, outside diameter approx. 8.5mm, weight approx. 129 kg/km, copper 73.7 kg/km |
|
LiYCY(TP) 4x2x0.5mm² (051390) Data cable shielded, twisted pair LiYCY(TP) 4x2x0.5mm², lead colour/no. according to DIN 47100, outside diameter approx. 9.1mm, weight approx. 146 kg/km, copper 82 kg/km |