Round cable halogen-free 24G1 with carrier element

Round travelling cable 24x1mm² with carrier element and supporting braid, halogen-free


Round travelling cable halogen-free

Construction cable

Bare, finest gauge copper strand, acc. to DIN EN 60228, class 6.
Lead insulation: halogen-free materials, black with white numerical imprint.
Leads stranded around a central carrier element.
Textile banding between the leads and the sheath.
Sheath: Ethylen Copolymer HM2 acc. to EN 50363-24, halogen-free, flame retardant acc. to IEC 60332-1-3.
Cable, flexible at low temperatures.

Application

Annotation

Travelling cable for lifts
Highly flexible, at medium mechanical stress in dry and damp rooms.

If travelling cables frequently hit blunt edges due to the up and down motion, the product life can be negatively impacted. For this reason it is recommendable to effect the mounting in the shaft at a smooth uncovered concrete wall.
Deliverable as cut goods or as a 500m drum.

G = with protective conductor

Cable assembly

Optionally the cable can be assembled on both sides.
The insulation of both sides will be stripped off, the leads become fitted with wire end sleeves.
No extra charge for individual lengths between 10cm and 45cm.

Specification

Bending radius flexible use: 12 x outer diameter
Rated voltage U0 /U 500V
Conductor resistance 19.5 Ω/km (at 20°C)
Temperature range flexible: -25°C up to +70°C
Maximum hoisting height 80m
Max. rated speed 1.6m/s

Products

Description
Round cable halogen-free 24G1 (051290)
Halogen-free round travelling cable 24x1mm² with carrier element, supporting braid and protective conductor, leads with numerical imprints according to VDE 0293, deliverable as ring max. 60m, for larger lengths it is necessary to roll the cable up on a drum, outside diameter approx. 22mm, weight approx. 580 kg/km, copper approx. 230 kg/km, hanging up length 45m.
Cable assembly for round travelling cable 24G1 (052608)
Cable assembly for the round travelling cable 24x1mm² (art.no. 51290). Without any further specifications the insulation of side A will be stripped off at a length of 30cm and side B at a length of 40cm, the leads become fitted with wire end sleeves.