PVC shielded, EMC conform, YSLCY-OZ

PVC control cable, shielded, EMC conform, YSLCY-OZ


PVC cable YSLCY-OZ, shielded

Construction cable

Bare, fine gauge copper strand, acc. to VDE 0295, class 5.
Lead insulation: PVC, black with white numerical imprints, acc. to VDE 0293-308.
Leads stranded in layers.
No inner sheath, instead insulating plastic foil. EMC-compatible shielding braid of tinned copper, covering degree approx. 85 %.
Sheath: special PVC compound, flame retardant and self-extinguishing acc. to IEC 60332-1-2.
The materials used during manufacturing are cadmium free and silicone free.

Application in general

Application in lift construction

Flexible cable, at medium mechanical stress in dry and damp rooms.
Outdoors only with protection against direct solar irradiance.
Not underground or underwater and only in compliance with the temperature limit values.
The copper shielding braid protects the environment against electromagnetic interference.
According to the Low Voltage Directive 2014/35/EU.

Suitable for wiring of:

  • main circuit between the lift control unit, the frequency converter and the motor
  • control circuit between the lift control unit, the frequency converter and the motor

Annotation

-O = without protective conductor
  Z = leads with numerical imprints

Deliverable as cut goods.

Specification

Bending radius flexible use: 20 x outer diameter
fixed installation: 6 x outer diameter
Nominal voltage U0 /U 300/ 500V
Coupling resistance with 30 MHz, approx. 250 Ω/km
Temperature range flexible: -15°C up to +70°C
fixed installation: -40°C up to +70°C

Products

Description
YSLCY-OZ 12x0.5 (063542)
PVC shielded control cable, leads with numerical imprints acc. to VDE 0293, outside diameter approx. 11.3mm, weight approx. 202 kg/km, copper approx. 104 kg/km
YSLCY-OZ 2x1.0 (051526)
PVC shielded control cable, leads with numerical imprints according to VDE 0293, outside diameter approx. 6.5mm, weight approx. 65 kg/km, copper approx. 51 kg/km
YSLCY-OZ 4x1.0 (051214)
PVC shielded control cable, leads with numerical imprints acc. to VDE 0293, outside diameter approx. 8.7mm, weight approx. 130 kg/km, copper approx. 74 kg/km